Looking for the US version of our site?

It looks like you're visiting from the United States. Our US site checks US roofs, with savings in dollars.

Go to the US site

Which generates more? Metered 2024 output

Solar panels in Cambridge vs Norwich

Solar panels in Cambridge generate more than solar panels in Norwich. In 2024 the typical Cambridge system made 871 kWh for every kWp of panels against 819 in Norwich, a gap of 6%, read from the meters of 416 and 64 real homes.

Sunlight explains about 17% of it. PVGIS puts Cambridge's sky 1% ahead (1,048 against 1,041 kWh per kWp for a well-placed roof); the rest of the 6% metered gap is what sits on the roofs in each place: direction, shade and age.

Cambridge roofs made about 6% more than Norwich roofs in 2024.

871 against 819 kWh per kWp at the median, from 416 and 64 real systems about 52 miles apart. 37% of Norwich systems beat the Cambridge median.

CB

Cambridge

871 median kWh per kWp

middle half 803–928 · 416 systems · 2nd of 49

NR

Norwich

819 median kWh per kWp

middle half 740–903 · 64 systems · 10th of 49

Does Norwich get less sun than Cambridge?

Two figures per place. The sky: what PVGIS models a well-placed 1 kWp at each area's centre would make from sunlight alone. The meters: what the typical system there actually made.

  • Cambridge
    Sky
    1,048 kWh per kWp
    Meters
    871 kWh per kWp
  • Norwich
    Sky
    1,041 kWh per kWp
    Meters
    819 kWh per kWp

Cambridge's sky delivers 1% more; the meters are 6% apart. Sun figures are modelled at a single point for an ideal roof, which is why every real system sits below them.

How much do solar panels generate in Cambridge and Norwich?

Solar panels in Cambridge

The middle half of 416 metered Cambridge systems made 803 to 928 kWh per kWp in 2024, and the best tenth cleared 955. A 4 kWp system, about ten panels, made roughly 3,210–3,710 kWh a year, worth about £370–£700 at 2026 prices, with payback in the region of 11–16 years on £5,600–£8,600 installed.

Full Cambridge solar output figures

Solar panels in Norwich

The middle half of 64 metered Norwich systems made 740 to 903 kWh per kWp in 2024, and the best tenth cleared 950. A 4 kWp system, about ten panels, made roughly 2,960–3,610 kWh a year, worth about £350–£680 at 2026 prices, with payback in the region of 11–17 years on £5,600–£8,600 installed.

Full Norwich solar output figures

What the gap is worth

The same 4 kWp system at each area's median, through the Solarable calculator at 2026 electricity and export prices.

  • More a year in Cambridge £20–£40 about 210 kWh more
  • Payback in Cambridge 11–16 years on £5,600–£8,600 installed
  • Payback in Norwich 11–17 years on £5,600–£8,600 installed

Ranges, because the figures move with your tariff and how much you use in the day. Run the numbers for your own roof.

What else the meters show

416 solar systems around Cambridge and 64 around Norwich were read from their own meters through 2024. The middle half in Cambridge made 803 to 928 kWh for every kWp of panels; in Norwich, 740 to 903.

PVGIS puts the sunlight gap at only 1%, so roughly 17% of the metered gap is sky and the rest is roofs.

The gap is real but thin. 37% of Norwich systems beat the Cambridge median of 871, and 29% of Cambridge systems fell short of the Norwich median. Pick the roof, not the postcode.

The best tenth of Norwich systems made 950 kWh per kWp or more, above the Cambridge median. A good roof in Norwich is a good roof anywhere.

That puts Cambridge 2nd of the 49 postcode areas we can measure and Norwich 10th, still above the British median of 766 kWh per kWp.

Both sets of figures are what real systems metered in 2024, so the gap mixes sunlight with system age, roof direction and shading. None of it says what one particular roof would do.

Do Norwich roofs ever beat Cambridge ones?

Both areas, grouped by what each system made. 37% of Norwich systems cleared the Cambridge median of 871. Location moves the odds; it does not decide the outcome.

Cambridge: the middle half of 416 systems made 803–928 kWh per kWp. Norwich: the middle half of 64 systems made 740–903 kWh per kWp.

Two certified installers fitting a solar panel on a tiled UK roof
Free roof check

Which side of the gap is your roof on?

Enter your postcode and we estimate your roof's direction, shade and solar potential from the air, then show certified installers covering your area.

  • Every installer is certified

Looking for someone to fit them? MCS-certified installers covering Cambridge and Norwich are listed in the Solarable directory.

Common questions

Cambridge and Norwich, answered.

Which is better for solar panels, Cambridge or Norwich?

Cambridge, by 6% on the 2024 medians (871 against 819 kWh per kWp). But 37% of Norwich systems beat the typical Cambridge one, so a good roof in Norwich outperforms an average roof in Cambridge. Compare your own roof, not the postcode.

Does Norwich get less sun than Cambridge?

A little. PVGIS puts the sunlight a well-placed roof receives at 1,048 kWh per kWp a year in Cambridge and 1,041 in Norwich, 1% apart. The metered gap is 6%, so sunlight is only part of the story.

Is solar still worth it in Norwich if Cambridge roofs make more?

Usually, yes. The middle half of Norwich systems made 740 to 903 kWh per kWp in 2024, and the best tenth cleared 950. On a 4 kWp system that is roughly £350 to £680 a year at 2026 prices, with payback in the region of 11 to 17 years. Whether your roof lands in that band depends on its direction and shade, which the roof check reads for your address and an installer survey confirms.

How much more would the same panels make in Cambridge than in Norwich?

At the two medians, a 4 kWp system made about 210 kWh more a year in Cambridge, worth roughly £20 to £40 at 2026 prices. That is the gap between typical systems, not a promise about any one roof: 37% of Norwich systems beat the Cambridge median.

Why do Cambridge roofs make more than Norwich roofs?

These are meter readings from real homes about 52 miles apart, so the gap mixes sunlight with how old the systems are, which way the roofs face and how much shade they sit in. PVGIS puts the sunlight difference at 1%; the rest is the roofs. 91% of Cambridge systems and 88% of Norwich systems face within 45° of south.

How many homes are these figures based on?

416 systems around Cambridge and 64 around Norwich, from Sheffield Solar's uk_pv dataset of 2024 meter readings. We only publish a postcode area once it clears a sample floor, and every figure is shown with the number of systems behind it. How we measure.

More comparisons

Output figures from openclimatefix/uk_pv (Hugging Face, CC-BY-4.0), collected by Sheffield Solar. Sun figures from EU PVGIS v5.2 (PVcalc, optimal fixed plane, 14% system loss), at each area's system centroid. Money figures use the Solarable calculator's 2026 assumptions. How we measure.